Keil Logo

A51: REVERSE ORDER DW KEYWORD


Information in this article applies to:

  • C51 Version 5.50a
  • C51 Version 6.10a

QUESTION

Is it possible to specify little-endian vs. big endian format for the A51 Assembler's DW instruction?

ANSWER

There is no way to specify the endianness of the DW directive, however, the following macro stores a word in reverse byte order:

RDW MACRO DWVAL
    IF NUL DWVAL
        EXITM
    ENDIF
    DB LOW DWVAL
    DB HIGH DWVAL
ENDM

Last Reviewed: Friday, January 5, 2001


Did this article provide the answer you needed?
 
Yes
No