Keil Logo

MCBSTR750: START PROBLEM ON POWER-UP


Information in this article applies to:

  • MCBSTR750 Evaluation Boards

QUESTION

I have a MCBSTR750 Starter Kit and after power-up the program does not start properly. Is there a work-around?

ANSWER

The problem is due to a missing clock stablization phase in the STR750.s file. Just add the following code which lets the clock stabilize after a power-up:

Reset_Handler


; Wait for clock to stabilize --------------------------------------------------

                LDR     R1, =10000
WAIT            SUBS    R1, R1, #1
                BNE     WAIT


; Setup Global Configuration Register ------------------------------------------

Last Reviewed: Wednesday, November 15, 2006


Did this article provide the answer you needed?
 
Yes
No
Not Sure
 
  Arm logo
Important information

This site uses cookies to store information on your computer. By continuing to use our site, you consent to our cookies.

Change Settings

Privacy Policy Update

Arm’s Privacy Policy has been updated. By continuing to use our site, you consent to Arm’s Privacy Policy. Please review our Privacy Policy to learn more about our collection, use and transfers